Notes:
2/8/2024 3:16:16 PM
2/13/2024 10:06:16 AM
***Nothing to be installed prior to isolation valve and backflow device except Y-Strainer when present***
1) Heads shall not spray on impervious surfaces.
2) Heads shall not spray on walls or fences.
3) Heads shall not be closer than 4 inches of the edge of hardscape.
4) No drinking or domestic uses allowed on irrigation lines, no swimming pool use or fountains.
5) City of Denton irrigation permit verification form must be completed and signed at final inspection.
6) Heads are not allowed in bar ditches when present.
7) For final inspection, irrigator's representative must be present.
8) For final inspection, all sod and plant material must be installed.
9) City ordinance sec.28-488.e: irrigation systems shall have separate zones based on plant material type, microclimate factors, topographic features, soil, conditions, and hydrological requirements.
10) Backflow device must be freeze protected with insulated bag and mock rock enclosure or heat tape.
11) Per City of Denton, Rain/Freeze sensor cannot be located on fence.